Scope : Covers Seamless and Welded, Black and Hot-Dipped Galvanized nominal (average) wall pipe for coiling, bending, flanging and other special purposes and is suitable for welding. Continuous-Welded pipe is not intended for flanging. Purpose for which pipe is intended should be stated on...
Online InquiryScope:
Covers Seamless and Welded, Black and Hot-Dipped Galvanized nominal (average) wall pipe for coiling, bending, flanging and other special purposes and is suitable for welding. Continuous-Welded pipe is not intended for flanging. Purpose for which pipe is intended should be stated on order.
Materials and Manufacture:
The steel for both seamless and welded pipe shall be made by one or more of the
following processes: open-hearth, electric furnace, or basic-oxygen. The weld
seam of electric-resistance welded pipe in Grade B shall be heat treated after
welding.
Chemical Requirements:
Type S |
Type E |
Type F |
|||
(electric- |
(furnace- |
||||
Grade A |
Grade B |
Grade A |
Grade B |
Grade A |
|
Carbon max. % |
0.25 |
0.30 |
0.25 |
0.30 |
0.3 |
Manganese % |
0.95 |
1.2 |
0.95 |
1.2 |
1.2 |
Phosphorous, max. % |
0.05 |
0.05 |
0.05 |
0.05 |
0.05 |
Sulfur, max. % |
0.045 |
0.045 |
0.045 |
0.045 |
0.045 |
Copper, max.% |
0.40 |
0.40 |
0.40 |
0.40 |
0.4 |
Nickel, max. % |
0.40 |
0.40 |
0.40 |
0.40 |
0.4 |
Chromium, max. % |
0.40 |
0.40 |
0.40 |
0.40 |
0.4 |
Molybdenum, max. % |
0.15 |
0.15 |
0.15 |
0.15 |
0.15 |
Vanadium, max. % |
0.08 |
0.08 |
0.08 |
0.08 |
0.08 |
Hot-Dipped Galvanizing:
Sets standards for coating of pipe with zinc inside and outside by the
hot-dipped process. Weight of coating must not average less than 1.8 oz. per
square foot and not less than 1.6 oz. per square foot.
Permissible Variations in Wall Thickness:
The minimum wall thickness at any point shall not be more than 12.5% under the
nominal wall thickness specified.
Permissible Variations in Weights per Foot:
Plus or minus 10%
Tensile Requirements:
Seamless and Electric-resistance-welded |
Continuous-Welded |
||
Grade A |
Grade B |
||
Tensile Strength, min., psi |
48,000 |
60,000 |
45,000 |
Yield Strength, min., psi |
30,000 |
35,000 |
25,000 |
Hydrostatic Testing:
Hydrostatic inspection test pressures for plain end and threaded and coupled pipe are specified. Hydrostatic pressure shall be maintained for not less than 5 seconds for all sizes of seamless and electric-resistance-weld pipe.
Mechanical Tests Specified:
Tensile Test -- Transverse required on ERW for NPS 8 and large. Sending Test
(Cold) -- STD and XS-NPS 2 and under XXS-NPS 1 1/4 and under.
Degree of Bend |
Diameter of Mandrel |
|
For Normal A53 Uses |
90 |
12 x nom dia. of pipe |
For Close Coiling |
180 |
8 x nom dia. of pipe |
Flattening Test -- NPS 2 and larger STD and XS. (Not required for XXS pipe.)
Lengths:
Standard Weight |
Single Random -- 16' - 22'. 5% may be jointers. If Plain Ends -- 5% may be 12' - 16'. |
Double Random -- Shortest Length 22', minimum average for order 35'. |
Extra Strong and Double Extra Strong |
Single Random -- 12' -22'. 5% may be 6' - 12'. |
Double Random (XS and lighter) -- Shortest Length 22', minimum average for order 35'. |
Lengths longer than single random with wall thicknesses heavier than XS subject to negotiation. |
General Information:
Couplings -- Applied handling tight. Couplings, 2" and smaller straight tapped, other sizes taper tapped. |
Thread Protection -- Applied to pipe 4" and larger. |
End Finish (unless otherwise specified) -- |
STD or XS, or wall thicknesses less than 0.500 in. (excluding XXS): Plain and beveled |
All XXS and wall thicknesses over 0.500 in.: Plain end square cut. |
a53 Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless1
Diameter & Tolerance:
For pipe ≤ NPS 11⁄2 [DN 40], the outside diameter at any point shall not
vary more than 1⁄64 in. [0.4 mm].
For pipe ≥NPS 2 [DN 50], the outside diameter shall not vary more than ±1%.
Galvanized
1), Zinc: The zinc used for the coating shall be any grade of zinc
conforming to Specification B 6
2), Weight of Coating—The weight of zinc coating shall be not less
than 1.8 oz/ft2[0.55 kg/m2] as determined from the average results of the
two specimens taken for test in the manner prescribed in 19.5 and not less
than 1.6 oz/ft2[0.49kg/m2] for either of these specimens. And testing the
weight of zinc according to ASTMB90
Common Uses:
- Low pressure systems
- Structural applications
- Mechanical components
- Bollards
- Casing
SUNRISE is well-known as one of the leading astma a53 black and hot dipped zinc coated welded and seamless steel pipe manufacturers and suppliers in China for its quality products and excellent service. We warmly welcome you to buy the quality and durable steel products from our factory.