1. Scope*

1.1 This specification2 covers nominal-wall-thickness welded tubes and heavily cold worked welded tubes made from the austenitic steels listed in Table 1, with various grades

intended for such use as boiler, superheater, heat exchanger, or condenser tubes.

1.2 Grades TP304H, TP309H, TP309HCb, TP310H, TP310HCb, TP316H, TP321H, TP347H, and TP348H are modifications of Grades TP304, TP309S, TP309Cb, TP310S, TP310Cb, TP316, TP321, TP347, and TP348, and are intended for high-temperature service such as for superheaters and reheaters.

1.3 The tubing sizes and thicknesses usually furnished to this specification are 1⁄8 in. [3.2 mm] in inside diameter to 12 in. [304.8 mm] in outside diameter and 0.015 to 0.320 in. [0.4 to 8.1 mm], inclusive, in wall thickness. Tubing having other dimensions may be furnished, provided such tubes comply with all other requirements of this specification.

1.4 Mechanical property requirements do not apply to tubing smaller than 1⁄8 in. [3.2 mm] in inside diameter or 0.015 in. [0.4 mm] in thickness.

1.5 Optional supplementary requirements are provided and,when one or more of these are desired, each shall be so stated in the order.

1.6 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each

system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.

The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.

1.7 The following safety hazards caveat pertains only to the test method described in the Supplementary Requirements of this specification. This standard does not purport to address all

of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific warning statement is given in Supplementary Requirement S7, NoteS7.1.

2. Referenced Documents

2.1 ASTM Standards: 3

A 262 Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels

A 480/A 480M Specification for General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip

A 1016/A 1016M Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stainless Steel Tubes

E 112 Test Methods for Determining Average Grain Size

E 213 Practice for Ultrasonic Examination of Metal Pipe and Tubing

E 273 Practice for Ultrasonic Examination of the Weld Zone of Welded Pipe and Tubing

E 527 Practice for Numbering Metals and Alloys (UNS)

2.2 ASME Boiler and Pressure Vessel Code:Section VIII 4

3. Ordering Information

3.1 It is the responsibility of the purchaser to specify all requirements that are necessary for material ordered under this specification. Such requirements may include, but are not

limited to, the following:

3.1.1 Quantity (feet, metres, or number of lengths),

3.1.2 Name of material welded tubes (WLD) or heavily cold worked tubes (HCW),

3.1.3 Grade (Table 1),

3.1.4 Size (outside diameter and nominal wall thickness),

3.1.5 Length (specific or random),

3.1.6 Optional requirements (13.6),

3.1.7 Test report required (see Certification Section of Specification A 1016/A 1016M),

3.1.8 Specification designation, and

3.1.9 Special requirements and any supplementary requirements selected.






Heat Treatment Requirements

Grade                      UNS Number                      Solutioning Temperature, min or range                         Quenching Method

All grades not individually below listed below

1900°F [1040°C]                                                A

...                                   S30815                           1920°F [1050°C]                                                                               B

TP309HCb                       S30941                          1900°F [1040°C]C                                                                               B

TP310H                          S31009                           1900°F [1040°C]                                                                                 B

TP310HCb                      S31041                           1900°F [1040°C]C                                                                               B

...                                 S31254                            2100°F [1150°C]                                                                                 B

TP316H                         S31609                           1900°F [1040°C]                                                                                  B

TP321                           S32100                           1900°F [1040°C]C                                                                                 B

TP321H                         S32109                           2000°F [1100°C]C                                                                                 B

...                                 S32654                           2100°F [1150°C]                                                                                   B

...                                 S33228                           2050°F [1120°C]                                                                                   B

...                                S34565                           2050°F [1120°C]–                                                                                  B

                                                                         2140°F [1170°C]                                                                                   B

TP347                           S34700                           1900°F [1040°C]C                                                                                B

TP347H                         S34709                           2000°F [1100°C]C                                                                                B

TP348                           S34800                          1900°F [1040°C]C                                                                                 B

TP348H                          S34809                          2000°F [1100°C]C                                                                                B

...                                S35045                           2000°F [1100°C]                                                                                   D

...                                S38815                           1950°F [1065°C]                                                                                   B

...                                N08367                           2025°F [1110°C]                                                                                   B

...                                N08904                           2000°F [1100°C]                                                                                   B

...                                N08926                           2010°F [1105°C]                                                                                   B



A Quenched in water or rapidly cooled by other methods, at a rate sufficient to prevent reprecipitation of carbides, as demonstrated by the capability of passing Practices

A 262, Practice E. The manufacturer is not required to run the test unless it is specified on the purchase order (See Supplementary Requirement S6). Note that Practices

A 262 requires the test to be performed on sensitized specimens in the low carbon and stabilized types and on specimens representative of the as-shipped condition of

the other types. In the case of low-carbon types containing 3 % or more molybdenum, the applicability of the sensitizing treatment prior to testing shall be a matter for

negotiation between the seller and purchaser.

B Quenched in water or rapidly cooled by other methods.

C A solution treating temperature above 1950°F [1065°C] may impair resistance to intergranular corrosion after subsequent exposure to sensitizing conditions in the

indicated grades. When specified by the purchaser, a lower temperature stabilization or re-solution anneal shall be used subsequent to the higher-temperature solution

anneal prescribed in this table (See Supplementary Requirement S4).

DCooled in still air, or faster.



Tensile and Hardness Requirements



Grade

UNS

Designation

Tensile

Strength,

min, ksi

[MPa]

Yield

Strength,

min, ksi

[MPa]

Elongation

in 2 in. or

50 mm,

min, %

Rockwell

Hardness

Number,

max

TP201

S20100

95 [655]

38 [260]

35

B95

TP202

S20200

90 [620]

38 [260]

35

B95

TP304

S30400

75 [515]

30(205)

35

B90

TP304L

S30403

70 [485]

30(205)

35

B90

TP304H

S30409

75 [515]

25(170)

35

B90

TP304N

S30451

80 [550]

35 [240]

35

B90

TP309S

S30908

75 [515]

30 [205]

35

B90

TP309H

S30909

75 [515]

30 [205]

35

B90

TP309Cb

S30940

75 [515]

30 [205]

35

B90

TP310S

S31008

75 [515]

30 [205]

35

B90

TP310H

S31009

75 [515]

30 [205]

35

B90

TP310Cb

S31040

75 [515]

30 [205]

B90

TP316

S31600

75 [515]

30 [205]

35

B90

TP316L

S31603

70 [485]

25 [170]

35

B90

TP316H

S31609

75 [515]

30 [205]

35

B90

TP316N

S31651

80 [550]

35 [240]

35

B90

TP317

S31700

75 [515]

30 [205]

35

B90

TP317L

S31703

75 [515]

30 [205]

35

B90

TP321

S32100

75 [515]

30 [205]

35

B90

TP321H

S32109

75 [515]

30 [205]

35

B90

TP347

S34700

75 [515]

30 [205]

35

B90

TP347H

S34709

75 [515]

30 [205]

35

B90

30 [205]

35

B90

A Not applicable to tubes less than 1⁄8 in. [3.2 mm] in outside diameter or having wall thickness below 0.015 in. [0.4 mm], or both. The tensile properties of such

small diameter or thin wall tubes shall be a matter of agreement between the manufacturer and the purchaser.










Standard/Item

Outside Diameter

Thickness

Length

ASTM A249

O.D .<

25mm

+0.10mm

, -0.11mm

±10%

O.D. < 50.8mm +3.0mm

25mm

O.D.

40mm

± 0.15mm

-0mm

40mm <

O.D. <

50mm

±0.20mm

O.D. 50.8mm +5.0mm

50mm

O.D. <

65mm

±0.25mm

-0mm

65mm

O.D. <

75mm

±0.30mm

75mm

O.D.

100mm

±0.38mm

100mm <

O.D.

200mm

+0.38mm

, -0.64mm

200mm <

O.D.

225mm

+0.38mm

, -1.14mm